The temperature control equipment of the electric heater must ensure a certain working temperature
Aug 25,2022
Author:
Views:
During the maintenance or shutdown of the electric heater, the main power switch should be disconnected, and then relevant tests and disassembly inspections should be carried out. After the unit is shut down, the use of the temperature control equipment of the electric heater should be detected immediately to ensure that the problem is found early and there is enough time to deal with it. If the insulation resistance is lower than 1MΩ, the cable head should be removed, and the insulation resistance of the cable and the electric heater should be measured separately to distinguish whether the problem is the cable or the electric heater. If the three-phase DC resistance is found to be unbalanced, the cable and electric heater should also be measured separately to determine the specific location and temperature.
Each group of three-phase DC resistance and each phase insulation resistance, and make a record. At the same time, do the core pulling inspection of the electric heater, remove the dust in the heater, clean the scale of the electric heater, check the appearance and tightening of the electric heater, tighten the connection wires in the control cabinet, check and verify the thermometer and Whether the temperature controller is operating normally. Before starting the unit, the insulation resistance of the heater should also be measured again. If the insulation resistance of the individual group is found to be low, it cannot be sent to prevent damage to the electric heater or cable.
More News
What are the common refrigerator defrosting heater inspection and maintenance methods
1. The fan motor in the freezing room is damaged, resulting in no circulating cold air, so that the upper box has a certain degree of coldness, and the lower box is not cold. Inspection method: cut off the fan motor winding value, if it is infinite, it means that the fan motor winding is damaged due to open circuit, and the fan motor winding needs to be replaced. 2. The frost layer on the evaporator is too thick due to the damage of the defrost heater, the superheated defrost insurance or the open circuit of the bimetal defrost thermostat, which blocks the gap between the warped sheets of the evaporator and cannot pass the cold air. Maintenance method: Check the status of defrost heater, superheat defrost insurance, bimetal defrost thermostat, and replace damaged components.
Aug 25,2022
View More >How to calculate the heating power of electric heater
1. Power during operation. Power - Heat loss in the system. All calculations should take into account the worst case: lowest ambient temperature, shortest operation, highest cycle operation, maximum weight of temperature heating medium (flowing medium as maximum flow). 2. Steps to calculate the heater power: According to the process, draw the heating process flow chart (does not involve the material form and specification). 3. Calculate the heat required for the process. Calculates the amount of heat and time required to start the system. Draw the heating process flow chart, consider the appropriate safety factor, and determine the total power of the heater. Determine the sheath material and power density of the heating element, determine the size and quantity of the heater, and determine the power supply and control system of the heater.